XARTU/5™ Manual Copyright© 2013
Eagle Research Corporation
®
REV 11.1.11 Page | 31
System analysis using flow rate and pressure
Support for estimating gas volume consumption in cases of meter or instrument
malfunction
Configuring Four Parameters for display
This feature allows the user to configure four parameters that can be shown at the
same time on the display. It is helpful when troubleshooting the unit. The parameters
must be configured before they can be displayed. To configure and display the four
parameters:
1. Move to the first parameter to be configured.
2. Press the jump key followed by the blue zero key. The RTU will display:
Select 1234 for
XX-XX-XX
Where XX-XX-XX is the address for the parameter.
3. Press the number 1, 2, 3 or 4 for the desired positioning of the parameter.
Position 1 XX.XX XX.XX Position 2
Position 3 XX.XX XX.XX Position 4
4. Move to the second, third, and fourth parameters and follow steps #2 and #3
above.
5. Press the decimal point key () while in configuration mode to display the values of
all
four parameters. Pressing the decimal point key () a second time will show the
address
for the four parameters.
6. Press the decimal point key () a third time to exit to configuration mode.
Special Key Combinations
There are a number of special key combinations that allow the user to view system
information and perform certain tasks very easily. They are listed in the table below.