Opening to report each time the control panel is disarmed. If selecting Opening Report,
do
not
select Opening Report After Alarm. If reporting Opening by User, user code will be
transmitted automatically in Extended Format.
Program Opening Report After Alarm to report only when disarming after an alarm. This
feature may be used by the central station to verify that the subscriber has responded to the
alarm and disarmed the control panel. If Opening Report After Alarm is selected, do
not
select
Opening Report.
Panic Zone (Zone 5). When using Zone
5
for Panic,
program 24-Hour
Protection and Report
On Alarm. Note that if Zone
5
is not programmed for 24-Hour Protection, Panic may still be
activated when disarmed, but 5” will be displayed red LED will flash.
Program Enable Keypad Panic on Zone 5. Panic Zone is accessed by pressing Keys
[
*]
and
[#])
simultaneously
activating communicator to alert central station.
External panic switches may be used on Zone 5 terminals. Do not program Zone 5 for
Restore Report, or a restore will be sent as soon as buttons are released.
Pre-Dial Delav. May be used whenever a delay is required before dialing. It is usually required
to program Dial-Tone Detection, which causes the communicator to wait for a dial tone before
dialing (see Dial-Tone Detection). Certain telephone exchanges send a nonstandard dial tone
that the communicator may not be able to detect. With these exchanges, it is possible to
program Pre-Dial Delay rather than Dial-Tone Detection. This will cause the communicator
to wait for a predetermined period of time before dialing rather than look for a nonstandard
dial tone.
Contact telephone-equipment supplier to find out how long a delay is required before
dialing. Program one
d
for each 4-second delay required.
Priori
tv
Zone, A zone that will prevent arming if in trouble. If an attempt is made to arm, the
sounder will sound continuously and a
P”wil1
be displayed. Priority condition may be silenced
by disarming. Any zone may be selected as a Priority Zone. A zone in trouble that is neither
a Priority Zone nor an Auto-Bypass Zone will cause an alarm on arming.
Receiver Format, The communicator can be programmed to transmit to any standard
central-station receiver. A receiver format must be entered for each telephone number used,
but a different format may be assigned to each.
Call the central station for each telephone number used to confirm the type of receiver in
use. Select the receiver format entry for each telephone number from the following table.
Reuort on Alarm, When a zone selected to Report on Alarm is tripped, communicator
transmits code for that zone to central station. Enter Alarm Codes for each zone to report on
alarm, even if identical codes are used for different zones.
DATA
DUTY
CYCLE
INTERDIGIT
ENTRY RECEIVER FORMAT
FREQ.
(ON/OFF)
TIME
(BLANK) Ademco, Silent Knight
slow
1900Hz
6
0/40mS
600mS
1
Radionics, DCI, Franklin slow
18OOHz
60/40mS
600mS
2
Sescoa, Vertex, DCI, Franklin
1800Hz
3o/uhns
3 Radionics
fast
1800Hz
W12mS
4OOmS
4
Silent
Knight fast
l!WOHz
4Of3OmS
560mS
11