ES2400 – ES2403 – ES4800 - ES6000
User's Manual
___________________________________________________________________________________________________________________________________________________
When the jumper is set to position NORMAL, the MRG controller works normally.
When the jumper is set to position TEST, the MRG controller performs the complete charge
cycle in seconds, instead of minutes.
When a battery is connected:
if the voltage is lower than the gassing value, the EagleSmart will go in Emergency
Stop after 20-30 seconds.
If the voltage is higher than the gassing value, the EagleSmart will terminate the
charge and pass to the automatic equalize in a few seconds.
- End of manual -
__________________________________________________________________________________________________________________________________________________
Page 14/14
ATTENTION!
It's always necessary to keep the battery disconnected
while moving the QuickTest jumper.
ATTENTION!
After performing a quick test cycle, make sure to move the jumper to
position NORMAL before to put the charger in service.
If the QuickTest jumper remains in position TEST, each charge
cycle will terminate within 20-30 seconds, therefore the battery will
not be charged!