Programming Functions (cont'd)
Disable All: If Master Code is used, disables all 100 User\Manager Codes and clears all 3 Service Codes. If
a Manager Code is used, disables all Users (even across multiple Banks) under that Manager.
Disable Users Only: If Master Code is used, disables all 90 Users and clears all 3 Service Codes, while Manag-
ers remain active. If a Manager Code is used, disables all Users (even across multiple banks) under that Man-
ager.
Enable All: If Master Code is used, re-enables all 100 User/Manager Codes (Service Codes must be re-
programmed). If a Manager Code is used, re-enables all Users (even across multiple Banks) under that Man-
ager. Note: Managers cannot disable themselves. Use Function 944 to restore Functions 955 and 950. In
addition, if Codes are disabled using Function 955 or 950, and a new User Code is subsequently added (or an
existing Code changed), the new (or changed) User Code will automatically become enabled.
Enable/Disable All
Disable All
[ __ __ __ __ __ ] ;955;
Master/Manager Code**
Enable All
[ __ __ __ __ __ ] ;944;
Master/Manager Code**
[ __ __ __ __ __ ] ;950;
Master/Manager Code**
Disable Users Only
Next Free Code Address Locator ; 7 ;
Using the same method of beeps and flashes used in the Code Location Function, and dependent on the Mas-
ter or Managers Code entered, the lock will report the next available address for User Access Code program-
ming.
Report Sequence
1. At the start of the Next Free Code Location function, the lock will Flash both the GREEN and RED LEDs and will emit a low tone.
2. The lock will identify the Bank number by flashing the GREEN LED and beeping the sounder from 0 -9 times.
3. To signify the end of the Bank number ID sequence, the lock will flash both the GREEN and RED LEDs and will emit a low tone.
4. The lock will identify the User number by flashing the GREEN LED and beeping the sounder from 0-9 times.
5. To signify the end of the Code Location function, the lock will flash both the GREEN and RED LEDs and will emit a low tone. If no free
address is found, then the lock will emit a programming error tone sequence. No LED flashes/sounder beeps represent the number
zero.
Be sure to record all Code locations in the blank worksheet (page 4) for future reference. If the location of a Code is
not known, use this function to find the Code. The lock will identify the BANK (0-9) and USER (0-9) by beeping and
flashing the GREEN LED 0 to 9 times as detailed below.
Code Location Function ; 6 ;
[ __ __ __ __ __ ] ; 6 ; [ __ __ __ __ __ ]
Master/Manager Code** Code 2 - 5 digits
If the code entered is recognized, the following sequence will occur:
1. At the start of the Code Location sequence, the lock will Flash both the GREEN and RED LEDs and will emit a low tone.
2. The lock will identify the Bank number by flashing the GREEN LED and beeping the sounder from 0 -9 times.
3. To signify the end of the Bank number ID sequence, the lock will flash both the GREEN and RED LEDs and will emit a low tone.
4. The lock will identify the User number by flashing the GREEN LED and beeping the sounder from 0-9 times.
5. To signify the end of the Code Location function, the lock will flash both the GREEN and RED LEDs and will emit a low tone.
Note: Should the Code not be recognized, the lock will sound 5 beeps with a RED LED. When the Bank and/or slot numbers are
zero, the GREEN LED will not flash and the sounder will not beep.
** Required only if DL1200 is locked.
[ __ __ __ __ __ ] ; 7 ;
Master/Manager Code**