1
Trilogy
Double-Sided DL5200, DL5300 & PDL5300
Installation Instructions
WI1623B 10/08
GENERAL DESCRIPTION
This double-sided stand-alone door lock provides con-
trolled entry and exit at locations such as airport security
areas and police stations. The PDL5300 features an
HID compatible ProxCard
®
reader, and both the DL5300
and PDL5300 feature a real-time clock/calendar that
automatically adjusts for Daylight Saving Time and al-
lows for automated programming of events.
Double-Sided Description
Both sides of the lock contain keypads, keyholes, levers
and proximity readers. To differentiate between the two
sides of the lock, these instructions refer to the "primary"
side and the "secondary" side. The primary side con-
tains the ribbon cable; inserting the metal key into its
lock cylinder will always unlock the latch, allowing entry
or exit. The secondary side contains no wires; insert-
ing the metal key into its lock cylinder will NEVER unlock
the latch. The key inserted into the secondary side
ONLY allows removal / installation of the secondary
side lever.
Note: Even if the secondary side screws were tam-
pered with and removed--and the secondary side
lever removed--the lock is specifically designed to not
be mechanically unlocked from the secondary side.
Important: Because the metal key will not unlock the
latch from the secondary side, we highly recommend
that this lock never be installed into the sole exit door of a
room. You must thoroughly consider all situations (such
as panic exit due to fire) before deciding where this lock
is to be installed and which side of the lock will be in-
stalled on which side of the door.
345 Bayview Avenue
Amityville, New York 11701
For Sales and Repairs 1-800-ALA-LOCK
For Technical Service 1-800-645-9440
Publicly traded on NASDAQ Symbol: NSSC
© ALARM LOCK 2008
DOOR PREPARATION
1. Fold and place template on high edge of door at the
recommended height from floor. See Fig. 1.
2. Mark hole centers on door and door edge.
3. Drill 3/8" thru-bolt holes first, then drill 2 1/8" hole.
For Hardwood Doors:
Notch on both sides of 2 1/8" hole to accommodate
mounting plate tabs.
MAIN PROCEDURES
GENERAL DESCRIPTION .............................................. 1
DOOR PREPARATION ................................................... 1
INSTALLATION JIG ...................................................... 2
LATCH INSTALLATION ............................................... 2
STRIKE INSTALLATION .............................................. 2
LOCK PREPARATION ..................................................... 2
ADJUSTING FOR DOOR THICKNESS ...................... 3
TO REVERSE LEVER HANDING ............................... 3
LOCK INSTALLATION .................................................. 3-5
INTERCHANGEABLE (IC) LOCKS ............................... 5
INSTALL INTERCHANGEABLE (IC) CORES .............. 5
CHANGING AN EXISTING IC CORE ............................. 6
REMOVING THE IC CORE & LEVER ............................ 6
PROGRAMMING ....................................................... 6
TROUBLESHOOTING ............................................... 6
WIRE CONNECTIONS .............................................. 7
NAPCO LIMITED WARRANTY ....................................... 8
"PRIMARY SIDE" "SECONDARY SIDE"
RIBBON
CABLE
BATTERY
COMPARTMENT
FIG. 1: FOLD AND PLACE TEMPLATE ON DOOR
1-3/4" (44MM)
OR
1-3/8" (35MM)
DOOR
THICKNESS
C
OF DOOR
EDGE
L
VERTICAL
C
OF
LOCK
L
MARK
HEIGHT
LINE
HORIZONTAL
C
OF
LEVER
L